Renovation · CEC Section 26 Outlet Spacing

Room Circuit Planner

Rough out the required receptacle outlets, lighting circuits, and wire requirements for any newly framed or renovated room.

1. Room Layout Specs

2. Recommended Outlets & Circuits

CEC 12ft (3.6m) Receptacle Rule
MINIMUM REQUIRED RECEPTACLES
5 Outlets
RECOMMENDED BRANCH CIRCUITS
2 Circuits (1 AFCI Plug + 1 Light)
WIRE GAUGE RECOMMENDATION
14/2 NMD90 Copper (15A)
CEC Rule 26-712: No point along unusable wall space shall be further than 1.8 m (6 ft) from a receptacle (12 ft / 3.6 m maximum spacing).

Receptacle Placement Rules

  • Any usable wall space 900 mm (3 ft) or wider requires a receptacle.
  • Hallways longer than 4.5 m (15 ft) require at least one outlet.
  • Bedroom and living room receptacle circuits must be AFCI protected at the breaker.
Planning a floor's circuits
Rooms + loadsGeneral lighting loadCircuits neededGeneral lighting allowance comes from CEC Sec. 8-210.
Ad slot — calculator page banner

Need an electrician for your project?

The Riley Group Electrical provides licensed, insured electrical services across Durham Region and the GTA. For panel upgrades, EV chargers, renovations, or troubleshooting, reach out today.

Licensed & insured ESA# 7011454 Durham Region & the GTA
Visit therileygroup4.com → ✉ Email Us