Renovation · CEC Section 26 (Kitchen Branch Circuits)
Kitchen Renovation Electrical Load Calculator
Calculate mandatory CEC countertop circuits, appliance branch circuits, and total kitchen demand load for a kitchen remodel.
1. Kitchen Appliance Plan
2. Mandatory Kitchen Circuits
CEC Section 26 MandatoryTOTAL REQUIRED BRANCH CIRCUITS
6 Circuits
COUNTERTOP RECEPTACLE CODE
2x 20A T-Slot GFCI Circuits
TOTAL KITCHEN DEMAND LOAD
42 Amps @ 240V
CEC Rule 26-722 Compliant: Countertop outlets must be spaced no further than 900 mm (3 ft) from any point along counter.
CEC Section 26 Kitchen Rules
- Countertop receptacles require GFCI protection if within 1.5 m (5 ft) of the sink edge.
- Receptacles installed in kitchen islands or peninsulas must be fed from dedicated countertop circuits.
- Refrigerator requires a dedicated 15A branch circuit not shared with countertop outlets.
Ad slot — calculator page banner
⚡
Need an electrician for your project?
The Riley Group Electrical provides licensed, insured electrical services across Durham Region and the GTA. For panel upgrades, EV chargers, renovations, or troubleshooting, reach out today.
Licensed & insured
ESA# 7011454
Durham Region & the GTA