Renovation · CEC Section 26 & 68 (Wet Locations)

Bathroom Renovation Electrical Load Calculator

Calculate GFCI outlet requirements, exhaust fan/heater sizing, and floor warming circuit loads for a bathroom reno.

1. Bathroom Fixture Details

2. Bathroom Circuit Plan

CEC GFCI Class A
RECOMMENDED CIRCUITS
2 Dedicated Circuits
TOTAL BATHROOM LOAD
1,600 Watts (13.3A)
MANDATORY PROTECTION
Class A GFCI (5mA)
CEC Rule Compliant: All bathroom outlets within 1.5m of washbasin require Class A GFCI protection. Switches must be at least 1m from tub/shower.

CEC Section 26 & 68 Bathroom Rules

  • Receptacles in bathrooms must be fed by a dedicated 15A or 20A branch circuit or not overload hair dryer/curling iron draw.
  • In-floor heating systems over 1000W should be fed on a dedicated 120V or 240V GFCI thermostat circuit.
  • Light fixtures located directly inside or above a tub/shower enclosure must be wet-location rated and GFCI protected.
Ad slot — calculator page banner

Need an electrician for your project?

The Riley Group Electrical provides licensed, insured electrical services across Durham Region and the GTA. For panel upgrades, EV chargers, renovations, or troubleshooting, reach out today.

Licensed & insured ESA# 7011454 Durham Region & the GTA
Visit therileygroup4.com → ✉ Email Us