Renovation · CEC Section 28 (Motors & HVAC Equipment)
Heat Pump / AC Load Calculator
Size circuit breaker ratings, Minimum Circuit Ampacity (MCA), and Max Overcurrent Protective Device (MOPD) for central heat pumps and mini-split units.
1. HVAC Nameplate Details
2. Circuit & Wire Sizing
CEC Section 28 HVACRECOMMENDED BREAKER SIZE
30A 2-Pole Breaker
MINIMUM COPPER NMD90 WIRE
10/2 Copper Wire (30A rating)
OUTDOOR DISCONNECT REQUIREMENT
30A Fused / Non-Fused Disconnect
CEC Rule 28-604: An outdoor weatherproof disconnect switch must be installed within sight of the heat pump compressor unit.
HVAC Sizing Rules
- Wire gauge is sized strictly according to Minimum Circuit Ampacity (MCA).
- Breaker size is selected up to the Maximum Overcurrent Protective Device (MOPD) stamped on unit nameplate.
- It is normal under CEC Section 28 for breaker rating to be larger than wire ampacity due to motor inrush starting currents.