CEC Part I · Section 8 (Circuit Loading and Demand Factors)
Household Load Calculator
Estimate your home's total electrical demand load — the number that determines what service size you actually need. This is a simplified, educational version of the real CEC Section 8 calculation.
1. Home & Appliance Details
2. Estimated Demand Load
CEC Section 8TOTAL DEMAND LOAD
— W
EQUIVALENT SERVICE CURRENT (240V)
— A
Suggested minimum service: Enter your home's details to see a suggestion.
This is a simplified estimate. The real CEC Section 8 calculation applies additional demand factors to appliances, heating, and other loads that this tool doesn't fully model. Use this to get a rough sense of scale, then confirm the exact number with a licensed electrician's load calculation before sizing a real service.
How this estimate is built
- Basic load: 5000 W for the first 90 m² of living area, plus 1000 W for each additional 90 m² or portion — covers general lighting and receptacles.
- Electric range: 6000 W flat for a range up to 12 kW, plus 40% of any rating above 12 kW.
- Dryer: counted at a flat 5000 W if present.
- Water heater, space heating, and other 240V loads: counted at 100% of the connected load you enter (the real code allows some diversity here that this tool doesn't apply).
Adding up a home